Second-Degree AV Block Mobitz I ECG

ECG course

Second-degree Mobitz I, also known as the Wenckebach, is a cardiac conduction disorder characterised by progressive prolongation of the PR interval until a P wave is not conducted to the ventricle.

Second-degree AV block Mobitz I. ECG criteria

  • Progressive prolongation of the PR interval with each cycle, until a P wave fails to conduct to the ventricle (blocked P wave).
  • Repeating cycle ( Wenckebachphenomenon): conduction resumes with a shorter PR after the blocked beat.
  • Interval Progressively shortening RR before the blocked beat.
Bloqueo AV 2 grado Mobitz 1 ECG
Second-degree atrioventricular block type 1 (Wenckebach)

Second-degree AV block Mobitz I. Causes

  • Increased vagal tone: Common in athletes, young people and during sleep.
  • Drugs that depress AV conduction: beta-blockers, calcium channel blockers (non-dihydropyridine), digoxin, amiodarone.
  • Heart disease:
    • Ischaemia myocardial (particularly in inferior infarction).
    • Myocarditis (Lyme disease, sarcoidosis, Chagas disease).
    • Heart disease degenerative (Lev and Lenègre disease).
  • Cardiac procedures: Cardiac surgery, ablation in the septal region or after heart transplantation.
  • Metabolic disorders: Hyperkalaemia, hypothyroidism.

Second-degree AV block Mobitz I. Pathophysiology

Type 1 AV block is benign in most cases, caused by decremental conduction in the AV node. It is commonly associated with increased vagal tone and is usually located at the level of the AV node rather than the His-Purkinje system, which explains its good prognosis in most patients.

Second-degree AV block Mobitz I. Clinical significance

  • In patients young people and athletes, it is usually benign and needs no treatment.
  • In the setting of myocardial ischaemia, especially inferior infarction, it may be transient and resolve with reperfusion.
  • If it presents with symptoms such as syncope or dizziness, the risk of progression to more advanced block must be assessed.
  • When it occurs in patients with structural disease of the conduction system, there is a risk of progression to high-grade AV block.

Similar Posts

  • PR Interval ECG

    Complete guide to ECG topics PR Interval ECG. Definition and Features The PR interval is measured from the start of the P wave to the start of the QRS complex. Its normal duration ranges from 120 to 200 milliseconds (ms) in adults. It represents the time needed for atrial depolarisation and conduction of the impulse through…

  • U Wave ECG

    The U wave is a less studied component of the electrocardiogram (ECG) that follows the T wave and can provide valuable information about late ventricular repolarisation and electrolyte homeostasis. Analysing it is essential in assessing electrolyte disturbances, heart disease and disorders of the autonomic nervous system. U Wave ECG. Features U Wave…

  • Sinus tachycardia ECG

    Link to the complete ECG course What is sinus tachycardia? Sinus tachycardia is a fast heart rhythm originating in the sinus node, the heart's physiological pacemaker. In most cases it is a normal response to stimuli such as exercise, stress or fever; however, when it is…

  • Atrial fibrillation (AF)

    Access the complete ECG guide What is atrial fibrillation (AF)? Atrial fibrillation (AF) is the most common sustained arrhythmia in clinical practice and its correct diagnosis by electrocardiogram (ECG) is essential for proper patient management. In this post we review the key electrocardiographic features of AF, diagnostic distinctions…

Leave a Reply