Pacemakers can be programmed to offer different pacing modes, adapting to each patient's specific needs. These modes determine how and when the pacemaker sends electrical impulses to the heart.

Marcapasos. Tipos De Estimulación

Pacemakers. Pacing Types: Coding System

The most common coding system for defining pacemaker pacing modes is the five-letter system (NBG, North American Society of Pacing and Electrophysiology / British Pacing and Electrophysiology Group). Although only the first 4 letters are used in routine clinical practice, the full code is as follows:

  1. First letter: Chamber of the heart paced (A: Atrium, V: Ventricle, D: Dual – Atrium and Ventricle).
  2. Second letter: Chamber in which cardiac activity is detected or sensed (A: Atrium, V: Ventricle, D: Dual).
  3. Third letter: Pacemaker response mode (I: Inhibited by spontaneous cardiac activity, T: Triggered, D: Dual – inhibited and triggered).
  4. Fourth letter: Rate modulation according to the patient's activity (R: Rate modulation).
  5. Fifth letter: Multisite pacing capability (not usually used).

The trick I used when studying it was to remember the letters of ESPaña (Spanish for Spain):

The E paced, the S sensed and the P for Pacing (that is, whether it paces or is inhibited)

Pacemakers. Most Common Pacing Types

1. AAI (Paces the atrium, Senses the atrium, with Inhibition)

AAI mode: This pacing mode is used mainly for patients with sinus node dysfunction but an intact atrioventricular conduction system. In AAI mode, the pacemaker paces the right atrium when it detects that spontaneous atrial activity is insufficient, and is inhibited if it detects an adequate natural rhythm.

  • Indications: Sinus node dysfunction with intact AV conduction.
  • Advantages: This mode preserves AV synchrony and avoids unnecessary right ventricular pacing.
  • Limitations: It is not useful in patients with atrioventricular block, as it cannot pace the ventricle.

2. VVIR (Paces the ventricle, Senses the ventricle, with Inhibition and Rate modulation)

VVIR mode: In this mode, the pacemaker only senses and paces the ventricle. When it does not detect adequate ventricular activity, the device generates an electrical impulse to pace the right ventricle. The "R" indicates that the device adjusts the pacing rate according to the patient's level of physical activity.

  • Indications: Patients with chronic atrial fibrillation or advanced AV block in whom atrioventricular synchrony cannot be restored (that is, atrial activity is ignored completely and the device is blind to it).
  • Advantages: Simplicity and effectiveness in patients who only need ventricular pacing.
  • Limitations: Because atrial activity is neither paced nor sensed, coordination between atrium and ventricle is lost, which can compromise cardiac output efficiency in some patients.

3. DDDR (Dual Pacing, Dual Sensing, Dual Response with Rate Modulation)

DDDR mode: This is one of the most widely used and versatile modes. The pacemaker can both pace and sense activity in the atrium and ventricle and responds accordingly. It can also adjust the pacing rate to the patient's activity level. DDDR mode maintains synchrony between atrium and ventricle, optimising cardiac performance.

  • Indications: Atrioventricular block, sinus node disease with AV block, or sinus dysfunction requiring rate response.
  • Advantages: Maintains optimal coordination between atria and ventricles, adjusting the rate to the patient's metabolic demand.
  • Limitations: It is more complex and requires closer follow-up to adjust the parameters properly.

4. VVI (Ventricular Pacing, Ventricular Sensing, Inhibited)

VVI mode: Similar to VVIR mode, but without rate modulation. The pacemaker only paces the ventricle when ventricular activity is insufficient, and is inhibited when it senses an intrinsic rhythm. This mode does not respond to changes in the patient's physical activity, so it is more limited in adapting to daily demands.

  • Indications: Atrioventricular block in sedentary patients or those with constant needs.
  • Advantages: Simple and effective for patients with insufficient ventricular rhythms.
  • Limitations: Does not adjust the rate to the patient's demand or maintain AV synchrony.

5. AAIR (Atrial Pacing, Inhibited, with Rate Modulation)

AAIR mode: Similar to AAI mode but with the added ability to adjust the pacing rate to the patient's physical activity. This mode is useful in patients with sinus dysfunction but an intact AV node.

  • Indications: Sinus node dysfunction in active patients, with modulation according to demand.
  • Advantages: Offers an adaptive rate response, improving exercise tolerance.
  • Limitations: Not suitable for patients with AV block, as it does not guarantee ventricular conduction.

6. VDDR (Ventricular Pacing, Dual Sensing, with Rate Modulation)

VDDR mode: This mode paces the ventricle while sensing activity in both chambers (atrial and ventricular), maintaining AV synchrony without the need for atrial pacing. It also modulates the rate according to the patient's demands.

  • Indications: Atrioventricular block with preserved atrial function.
  • Advantages: Maintains AV synchrony without direct atrial pacing, optimising cardiac function.
  • Limitations: Not suitable if the atrium does not have enough intrinsic activity to regulate the rhythm.

Pacemakers. Pacing Types: Which to Choose?

Choosing the most suitable pacing mode depends on several clinical factors:

  • Type of bradycardia: The type of cardiac dysfunction determines whether pacing is needed in one or both chambers of the heart, and whether rate modulation is needed.
  • Atrioventricular synchrony: Maintaining coordination between atrium and ventricle is essential to optimise cardiac output, especially in patients with heart failure.
  • Patient activity level: Rate-modulated modes are essential for physically active patients, allowing dynamic adjustment of heart rate during physical exertion.
  • Comorbidities: Additional conditions such as atrial fibrillation, AV block or sinus node dysfunction directly influence the choice of pacing mode.