Sinus Pause ECG. Clinical Case
66-year-old woman brought to the emergency department after syncope while standing in a supermarket, with secondary head injury. On arrival, blood tests are normal and the 12-lead ECG shows sinus rhythm at 70 bpm without abnormalities. An echocardiogram is also normal. Given the features of the syncope, it is decided to keep her on ECG monitoring for 24 hours in the emergency department, and the following is seen:

Sinus pause ECG
In this post we analyse this telemetry tracing showing a significant sinus pause, followed by a transient ventricular escape rhythm. Despite baseline wander, the tracing allows a diagnostic interpretation.

Step-by-Step Analysis of the Tracing
🕒 Interval 18:17:44 – 18:17:49
- Regular sinus rhythm.
- A P wave preceding each QRS complex (blue arrows).
- Narrow QRS complexes, normal morphology (red arrows).
- Stable heart rate (~75 bpm).
- Wandering baseline, but without diagnostic interference.
🕒 Interval 18:17:49 – 18:17:54
- Sudden disappearance of atrial activity.
- No P waves or QRS complexes for several seconds.
- Start of a sinus pause, with no immediate atrial or junctional escape activity.
- Diagnosis: significant sinus pause > 3 seconds (5.5 seconds), a major criterion of sinus node dysfunction.
🕒 Interval 18:17:54 – 18:17:59
- The monitor shows ASYSTOLE (a common semantic error of automatic monitors when they detect no QRS).
- Finally a wide QRS complex appears, not preceded by a P wave.
- Indicated by the green.
- Consistent with a ventricular escape rhythm: QRS >120 ms, different morphology, no atrial conduction.
- Subsequent rhythm: atrial activity recovers (P waves, blue arrows), followed by normal QRS complexes (red arrows).
- Sinus rhythm is restored.
Diagnostic Interpretation
ECG diagnosis:
Significant sinus pause (> 3 seconds) with transient ventricular escape.
Clinical diagnosis:
Sinus node dysfunction (sick sinus syndrome).
- The absence of P waves after the last beat before the pause indicates failure of sinus node automaticity (not a failure of conduction).
- The absence of a junctional escape also suggests possible involvement of the lower conduction system.
- The ventricular escape acts as a transient protective mechanism, but it is not enough to maintain an adequate rhythm.
Clinical Relevance of Sinus Node Dysfunction
Sinus node dysfunction can be:
- Intrinsic (degenerative, nodal ischaemia, age-related fibrosis).
- Worsened by drugs (beta-blockers, calcium channel blockers, digoxin, class I and III antiarrhythmics such as amiodarone).
Criteria for permanent pacemaker implantation:
- Symptomatic sinus pauses > 3 seconds.
- Sinus node dysfunction with symptomatic bradycardia.
- Tachy-brady alternation.
In this case, the long duration of the pause and the need for a ventricular escape suggest an indication for a pacemaker, especially if the patient had symptoms (syncope, dizziness, etc.).
Conclusion
This case is a teaching illustration of:
- The pathophysiology of a prolonged sinus pause.
- The absence of effective secondary pacemakers (junctional escape).
- Activation of the ventricular system as a last resort.
- The importance of recognising these patterns to indicate timely treatment.